CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube

Product Details
Customization: Available
Type: Guedel Tube Airway
Material: Semi-Rigid
Still deciding? Get samples of US$ 2/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
101~500 square meters
  • CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
  • CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
  • CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
  • CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
  • CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
  • CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
Find Similar Products
  • Overview
  • Product Parameters
  • Product Description
  • Company Profile
  • Certifications
  • Our factory
  • Payment and Shipping ,
  • FAQ
Overview

Basic Info.

Ethylene Oxide Sterilization
Ethylene Oxide Sterilization
Quality Guarantee Period
5 Years
Group
Adult
Logo Printing
With Logo Printing
Quality Certification
CE ISO
Length
Customized
Color
Transparent, Green and So on
Types
Tracheal Cannula
Transport Package
Carton/Box
Specification
Customized
Origin
China
HS Code
901839000
Production Capacity
1000000PCS/Month

Product Description

Disposable Guedel Oral Airway Tube Sterile Oropharyngeal Airway
The oropharyngeal airway was designed by Arthur Guedel.
An oropharyngeal airway (also known as an oral airway,OPA or Guedel pattern airway) is a medical device called an airway adjunct used to maintain or open a patient's airway. It does this by preventing the tongue from covering the epiglottis, which could prevent the person from breathing. When a person becomes unconscious, the muscles in their jaw relax and allow the tongue to obstruct the airway.
CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
 

Product Parameters

Item guedel tube airway
Material semi-rigid
Type tracheal cannula
Applicable medical use
Sample  free
Delivery 15-20 working days
Service OEM,can print your logo
 
CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
Size Length(mm) Color Pcs/ctn Carton size(cm)
000# 40 Pink 1000 52*38*52
00# 50 Blue 1000 52*38*52
0# 60 Black 500 52*38*52
1# 70 White 500 52*38*52
2# 80 Green 500 52*38*52
3# 90 Yellow 500 52*38*52
4# 100 Red 500 52*38*52
5# 110 Blue 500 52*38*52
6# 120 Orange 500 52*38*52

Product Description

How to Insert an Oropharyngeal (Guedel) Airway?

Advanced first aiders and first responders may be trained in the use of Oropharyngeal (OP) airways. These devices are sometimes called Guedel airways.

An OP may be required to achieve or maintain an open airway. The OP conforms to the shape of the palate. When inserted into an unconscious patient, it can assist in maintaining a clear airway by preventing obstruction by the tongue. This enables the passage of gases through and around the tube and facilitates suctioning (if trained).

Inserting an oropharyngeal (OP) airway

Select an appropriately sized OP. An oversized OP airway could obstruct the airway by depressing the epiglottis. The tongue could obstruct an airway that is too small. The correct size can be confirmed by placing the tube at the side of the cheek and ensuring it is level with the front of the teeth and reaches the angle of the jaw.

CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube

The airway should be inserted 'upside down' and it is then rotated as it nears the posterior wall of the pharynx so that it points downward.

CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube
CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube

An OP airway may be used for the unconscious child with an impaired gag reflex to relieve obstruction from the tongue. It may also be useful in maintaining an open airway during bag-valve-mask ventilation.

An OP airway will not prevent aspiration of stomach contents. It only stops the tongue from obstructing the back of the pharynx. The patient may still need to be placed in the recovery position in order to protect the airway from stomach contents. 

Always re-assess after performing any airway intervention.

Company Profile

CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube

Certifications

CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube

 

 

Our factory

CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube

Payment and Shipping ,

CE Approved Airway Guedel Oropharyngeal Airway Guedel Type for Tracheostomy Tube

FAQ

Q1: What kind of payment terms do you accept?
A1: We accept the payment terms as below(T/T, Western Union)

Q2: Can I place a sample order first for testing? 
A2: Yes, some of them can be free samples, you just need to pay for the transport fee. Please confirm the details with us. 

Q3: How long do I need to wait for the shipping?
 A3: 15 ~ 30 Days after the Order is Confirmed (depending on order quantity). 

Q4: Is it possible to use our own packing box/specified packing box? 
A4: For bulk orders, the box can be customized, we will confirm the design before packaging. 

Q5: Do you have inspection procedures for the products? 
A5: 100% self-inspection before packing. 

Q6: How about the price? Can you make it cheaper? 
A6: We always take the customer's benefit as the top priority. Price is negotiable under different conditions, and we assure you that get the most competitive price.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More